|
Chimney Parts
Insulated Pipe

Model SSII Type HT and Model SSII pipe with six diameter
sizes is produced in standard 18" and 36" lengths. Shorter
insulated pipe sections (3", 6" and 9" net lengths) are
available for use as insulated tee snout extensions or where small lengths
are needed. The various lengths can be intermixed to attain
virtually any height. The installed length per section of 18"
pipe is 16-3/4". The installed length of 36" pipe is
35-5/16".
| Model SSII Type HT |
| Part No. |
6T- |
7T- |
8T- |
| Overall Length |
4-1/4, 7-1/4, 10-1/4, 18, 36-9/16 |
4-1/4, 7-1/4, 10-1/4, 18, 36-9/16 |
4-1/4, 7-1/4, 10-1/4, 18, 36-9/16 |
| a. Length installed (in.) |
3, 6, 9, 16-3/4, 35-5/16 |
3, 6, 9, 16-3/4, 35-5/16 |
3, 6, 9, 16-3/4, 35-5/16 |
| b. Inside diameter (in.) |
6 |
7 |
8 |
| c. Outside diameter (in.) |
8 |
9 |
10 |
| Approx. weight per installed foot. (lbs.) |
5.8 |
6.7 |
7.5 |
| Minimum installed floor space (sq. ft.) |
1.0 |
1.2 |
1.4 |
| Model SSII |
| Part No. |
10S- |
12S- |
14S- |
| Overall Length |
4-1/4, 7-1/4, 10-1/4, 18, 36-9/16 |
4-1/4, 7-1/4, 10-1/4, 18, 36-9/16 |
4-1/4, 7-1/4, 10-1/4, 18, 36-9/16 |
| a. Length installed |
3, 6, 9, 16-3/4, 35-5/16 |
3, 6, 9, 16-3/4, 35-5/16 |
3, 6, 9, 16-3/4, 35-5/16 |
| b. Inside diameter (in.) |
10 |
12 |
14 |
| c. Outside diameter (in.) |
12 |
14 |
16 |
| Approx. weight per installed foot (lbs.) |
9.8 |
11.9 |
14.0 |
| Minimum installed floor space (sq. ft.) |
1.8 |
2.25 |
2.8 |
Insulated Tee

The insulated chimney tee may be used to start chimneys
indoors or outdoors using a wall support assembly or a masonry pier.
A length of insulated chimney pipe is attached to the Tee snout, using a
Locking Band, to pass safely through combustible walls. An insulated
Tee Cap is included which can be removed from bottom opening for
inspection and cleanout. Maximum height of chimney which can be
supported by an Insulated Tee is 50 feet.
| Model SSII Type HT |
Model SSII |
| Part No. |
A |
B |
C |
Part No. |
A |
B |
C |
| 6T-IT |
6-3/8" |
6-3/8" |
12-3/4" |
10S-IT |
8-3/8" |
8-3/8" |
16-3/8" |
| 7T-IT |
6-7/8" |
6-7/8" |
13-3/4" |
12S-IT |
9-3/8" |
9-3/8" |
18-3/4" |
| 8T-IT |
7-3/8" |
7-3/8" |
14-3/4" |
14S-IT |
10-3/8" |
10-3/8" |
20-3/4" |
Wall Support Kit

The Type HT Wall Support Kit has been tested for use fully
enclosed and has been designed in 6, 7 and 8 inch sizes to carry up to 50
feet of height. The capacity of the larger sizes 10, 12 and 14
inches is 40 feet of chimney. The Wall Support is intended for use
with the Insulated Tee as an interior or exterior support where the
chimney has a lateral connection. It is also useful where the pipe
connection passes through a combustible interior or exterior wall.
Braces may only be fastened to the wall below the plate for chimneys which
penetrate through the wall.
| |
Part No. |
A |
B |
C |
| Model SSII Type HT |
6T-WSK |
13" |
10-1/2" |
17" |
| 7T-WSK |
14" |
11-1/2" |
17" |
| 8T-WSK |
15" |
12-1/2" |
17" |
| Model SSII |
10S-WSK |
17" |
14-1/2" |
21" |
| 12S-WSK |
19" |
16-1/2" |
23" |
| 14S-WSK |
21" |
18-1/2" |
27" |
15°/30° Insulated
Elbows


15 degree Insulated Elbows can be used for fixed offsets
of 15 degree slope or in pairs for offsets adjustable from zero degrees to
30 degrees slope. The 30º Insulated Elbow in 6", 7" and
8" sizes can be used for fixed offsets of 30 degrees slope.
Greater angles are prohibited by UL Standard 103 and by the terms of the
product listing.
Locking Bands (one package with each elbow) allow 360
degree rotation and lock the components together in place at the exact
offset required. Insulated Elbows can be used at the same two-inch
air space clearance as chimney sections.
| |
Part No. |
A |
B |
| Model SSII Type HT 15° EL |
6T-EL15 |
11-5/8" |
3-1/16" |
| 7T-EL15 |
12-1/2" |
3-3/16" |
| 8T-EL15 |
12-5/8" |
3-5/16" |
| Model SSII 15° EL |
10S-EL15 |
13-5/8" |
3-9/16" |
| 10S-EL15 |
14-5/8" |
3-13/16" |
| 10S-EL15 |
15-5/8" |
4-1/8" |
| Model SSII Type HT 30° EL |
6T-EL30 |
12-1/2" |
6-1/4" |
| 7T-EL30 |
13-3/4" |
7" |
| 8T-EL30 |
14-3/4" |
7-3/8" |

| Part # |
2 offsets w/o pipe
O H |
2 offsets +3"
section O H |
2 offsets +6"
section O H |
2 offsets +9" section
O H |
2 offsets +18"
section O H |
2 offsets +36"
section O H |
| 6T-EL15 |
.80 |
6 |
1.6 |
9 |
2.4 |
11.9 |
3.1 |
14.8 |
5.1 |
22.2 |
9.9 |
40.2 |
| 7T-EL15 |
.83 |
6.3 |
1.6 |
9.2 |
2.4 |
12.1 |
3.2 |
15 |
5.2 |
22.5 |
10 |
40.4 |
| 8T-EL15 |
.86 |
6.6 |
1.7 |
9.5 |
2.5 |
12.4 |
3.2 |
15.3 |
5.2 |
22.8 |
10 |
40.7 |
| 10S-EL15 |
.93 |
7.1 |
1.7 |
10 |
2.5 |
12.9 |
3.3 |
15.8 |
5.3 |
23.3 |
10.1 |
41.2 |
| 12S-EL15 |
1.0 |
7.6 |
1.8 |
10.5 |
2.6 |
13.4 |
3.3 |
16.3 |
5.4 |
23.8 |
10.1 |
41.7 |
| 14S-EL15 |
1.1 |
8.1 |
1.8 |
11.1 |
2.6 |
14 |
3.4 |
16.9 |
5.4 |
24.3 |
10.2 |
42.3 |
| 6T-EL30 |
3.8 |
14.3 |
5.3 |
16.9 |
6.8 |
19.5 |
8.3 |
22.1 |
12.2 |
28.8 |
21.5 |
44.9 |
| 7T-EL30 |
4.0 |
14.8 |
5.5 |
17.4 |
7.0 |
20 |
8.5 |
22.6 |
12.3 |
29.3 |
21.6 |
45.4 |
| 8T-EL30 |
4.1 |
15.3 |
5.6 |
17.9 |
7.1 |
20.5 |
8.6 |
23.1 |
12.5 |
29.8 |
21.8 |
45.9 |
Ceiling Supports

The Finish Ceiling Support (FSP) in 6", 7" and
8" sizes, is finished in matte black and is available with either a
round or square trim plate.
The Ceiling Support (CSP) in sizes 10", 12" and
14", is un-painted and comes with a square trim plate only.
With proper framing, all ceiling supports assure at least
2" minimum clearance to combustibles at the support level and can
carry up to 50 feet of vertical chimney height.
| |
Part No. |
A |
B |
C |
C |
D |
| O.D. |
Framing Dimen. |
Sq. Plate Dimen. |
Rnd. Plate Dimen. |
From Ceiling |
| Model SSII Type HT |
6T-FSP* |
6-1/4" |
12-1/4" x 12-1/4" |
14-1/4" |
19" |
3-1/2" |
| 7T-FSP* |
7-1/4" |
13-1/4" x 13-1/4" |
15-1/4" |
21" |
3-1/2" |
| 8T-FSP* |
8-1/4" |
14-1/4" x 14-1/4" |
16-1/4" |
22" |
3-1/2" |
*Part No. T-FSP is square type trim plate.
* Part No. T-FSPR is round type trim plate.
| |
Part No. |
A |
B |
C |
D |
| O.D. |
Framing Dimensions |
Plate Dimensions |
From Ceiling |
| Model SSII |
10S-CSP |
10-1/4" |
16-1/4 x 16-1/4" |
18-1/2" |
3-1/2" |
| 12S-CSP |
12-1/4" |
18-1/4" x 18-1/4" |
20-1/2" |
3-1/2" |
| 14S-CSP |
14-1/4" |
20-1/4" x 20-1/4" |
22-1/2" |
3-1/2" |
Roof Support


An ideal support assembly for freestanding fireplaces and
open cathedral ceiling installations. Fits all roof pitches and
requires only simple framing. Mounts easily on to top of roof
through opening that allows 2-inch clearance. Maximum length of
chimney which can be suspended below is 20 feet. Maximum total
length is 30 feet.
The Roof Support Package (RSP) contains one 18"
length of pipe, roof brackets and necessary hardware.
The roof brackets and hardware may be purchased without
the pipe section by ordering a Roof Support Kit (RSK). The brackets
may be assembled to any standard pipe length at any desired height.
Locking bands must be used at each pipe joint when
installing either the RSP or RSK.
| |
Part No. |
A |
B |
Framing |
| Model SSII Type HT |
6T-RSP |
6" |
8" |
12" x *" |
| 7T-RSP |
7" |
9" |
13" x *" |
| 8T-RSP |
8" |
10" |
14" x *" |
| Model SSII |
10S-RSP |
12" |
12" |
16" x *" |
| 12S-RSP |
14" |
14" |
14" x *" |
| 14S-RSP |
16" |
16" |
16" x *" |
*Dimension varies depending on pitch of roof
Interior Resupport

Interior resupport assembly allows for two different
methods of chimney resupport. The first method is used when an
immediate section of chimney above the upper offset passes through a joist
area. With the appropriate Fire Stop/Wall Spacer (WS) in place,
clamp the support band around chimney and attach with six sheet metal
screws. The second means of support is used primarily when the
immediate sections of the upper offset do not pass through a joist area
and resupport is necessary. The Support Band is clamped around the
chimney immediately below a Locking Band. In both methods, the
straps are nailed to suitable framing at two inch clearance. The 18
foot limit of supportable chimney length applies.
Pert No.: 6T-IR, 7T-IR, 8T-IR, 10S-IR, 12S-IR,
14S-IR
Attic Insulation Shield

Used wherever a Ceiling Support, Finish Support, or Fire
Stop is installed below an open attic. The Insulation Shield is
required to guard against the hazard of blown-in or blanket insulation
filling any framed opening or contacting the chimney and possible storage
of combustibles against the chimney. Adaptable design usable for new
and retrofit installations. Half cylinder passes easily through
ceiling openings between 16" O.C. joists. Part can be removed
without cutting if attic is converted to habitable space and chimney is
fully enclosed. Readily trimmed for reduced height installation
close to eaves.
| |
Part No. |
A |
B |
| Model SSII Type HT |
6T-AIS |
16" x 16" |
12" |
| 7T-AIS |
16" x 16" |
13" |
| 8T-AIS |
16" x 16" |
14" |
| Model SSII |
10S-AIS |
18" x 18" |
16" |
| 12S-AIS |
20" x 20" |
18" |
| 14S-AIS |
22" x 22" |
20" |
Support Box

The Support Box is intended for use when installing a
model SSII chimney in an A-Frame, in a mobile home, or in a ceiling under
a narrow section of roof. It provides a finished installation at a
ceiling level and will support up to 20' of 6", 7" or 8"
diameter chimney. The part also can be used to provide shielding
from insulation when installed in unoccupied attic space. The
Support Box assembly is compromised of a black box designed for
installation inside 16" O.C. joists, a cylindrical shield, support
bucket, ceiling trim, and four screws.
| Part No. |
A |
B |
C |
| 6T-SB |
6-1/4" |
24" |
14-1/4" |
| 7T-SB |
7-1/4" |
24" |
14-1/4" |
| 8T-SB |
8-1/4" |
24" |
14-1/4" |
Roof Brace Kit
A roof brace Kit can be used whenever there is a need to
stabilize the chimney above the roof level. The purpose of the
bracing is to hold the chimney against wind load; and to prevent damage
from static and sliding snow. Up to 4' above the roof requires no
bracing. From 5' to 10' above the roof one T-RBK should be use, at a
midpoint on the chimney. Over 10' use on RBK 4' from the roof and
one RBK every 5' thereafter. Adjusts from 4' to 6'.
| |
Part No. |
| Model SSII Type HT |
6T-RBK |
| 7T-RBK |
| 8T-RBK |
Fire Stop/ Wall Spacer

Wall Band

Anchor Plate

Chimney Pipe Adaptor


Pitched Ceiling Plate

Fire Stop/Trim Collar

Finishing Collar


Dripless Smoke Pipe Adaptors

Round Top

The Round Top is designed to exclude rain and leaves and a
lower skirt to deflect wind for proper chimney draft.
Storm Collar
Flashings
Flashings are used to seal the opening where the chimney
penetrates the roof and to divert rain and snow down from the roof and
away from the chimney system. A series if adjustable flashings are
available depending on your roof pitch. A flat and low pitch
flashing is used to seal flat and low pitch roof (up to 2/12 pitch)
openings.
To determine your roof pitch, measure the number of inches
from the end of a level ruler down to the roof. This is the rise for
12" of run. A rise of 5" is a 5/12 pitch...4" a 4/12
pitch, etc.
Adjustable Flashing
Flat and Low Pitch Flashing

|